The blower W is located inside the HVAC/air conditioning
unit and can be removed without having to remove the HVAC
JCB Electronic Service Tool Diagnostic Kit High Quality
unit from the machine.
The only user-serviceable part is the resistor which
determines the blower motor speed. Other faults, excluding
wiring faults, necessitate the replacement of the blower unit
complete.
Resistor replacement requires the removal of the blower unit
as follows:
Removal
1
Disconnect the battery.
2
Gain access to the HVAC unit by removing the right
JCB ServiceMaster/WinEEM4 KG v2 Keygen
hand side console and remove the HVAC unit top cover,
refer to HVAC/Air Conditioning Unit – Removal and
Replacement Steps 2 and 3.
3
Disconnect the electrical connections to the blower.
4
Remove the screws securing the blower unit to
the HVAC unit housing.
5
Carefully withdraw the blower from the HVAC unit.
6
To remove the resistor, disconnect the electrical
connections and unscrew the resistor.
Replacement is the reverse of the removal procedure.
Freeze Protection Thermostat
– Removal and Replacement
The Thermostat V monitors the external temperature of the
evaporator and is located inside the HVAC/air conditionig
unit.
Removal
1
Disconnect the battery.
2
Gain access to the HVAC unit by removing the right
hand side console and remove the HVAC unit top cover,
refer to HVAC/Air Conditioning Unit – Removal and
Replacement Steps 2 and 3.
3
Unclip the sensor wire from the evaporator and
gently remove the wire from between the fins.
4
Disconnect the electrical connections to the thermostat.
5
Remove the screws securing the thermostat to
the HVAC unit housing.