The blower W is located inside the HVAC/air conditioning
unit and can be removed without having to remove the HVAC
JCB Electronic Service Tool Diagnostic Kit High Quality
unit from the machine.
The only user-serviceable part is the resistor which
determines the blower motor speed. Other faults, excluding
wiring faults, necessitate the replacement of the blower unit
JCB ServiceMaster/WinEEM4 KG v2 Keygen
complete.
Resistor replacement requires the removal of the blower unit
as follows:
Removal
1
Disconnect the battery.
2
Gain access to the HVAC unit by removing the right
hand side console and remove the HVAC unit top cover,
refer to HVAC/Air Conditioning Unit – Removal and
Replacement Steps 2 and 3.
3
Disconnect the electrical connections to the blower.
4
Remove the screws securing the blower unit to
the HVAC unit housing.
5
Carefully withdraw the blower from the HVAC unit.
6
To remove the resistor, disconnect the electrical
connections and unscrew the resistor.
Replacement is the reverse of the removal procedure.
Freeze Protection Thermostat
– Removal and Replacement
03.2026 JCB ServiceMaster 4 v26.3.2 Diagnostic Software with SW Files Download and installation
The Thermostat V monitors the external temperature of the
evaporator and is located inside the HVAC/air conditionig
unit.
Removal
1
Disconnect the battery.
2
Gain access to the HVAC unit by removing the right
hand side console and remove the HVAC unit top cover,
refer to HVAC/Air Conditioning Unit – Removal and
Replacement Steps 2 and 3.
3
Unclip the sensor wire from the evaporator and
gently remove the wire from between the fins.
4
Disconnect the electrical connections to the thermostat.
5
Remove the screws securing the thermostat to
the HVAC unit housing.