caterpillar 320E Excavator AWS Common Battery Problems

Possible Causes

• Charging Circuit

• Battery

• Auxiliary Devices

Recommended Actions

Follow the steps listed above in order.

1. Charging Circuit A. Check if the battery charging circuit is working properly. See Troubleshooting, “Alternator Faults”.

Charging

Result: Charging circuit malfunction.

Repair: Repair the charging circuit if necessary.

Result: Charging circuit is working properly. Proceed to test step 2.

2. Battery

A. Confirm that the battery can no longer hold its charge. See System Operation/Testing and Adjustment, “Battery – Test”.

Result: One battery is malfunctioning.

Repair: Replace the faulty battery. Refer to the Operation and Maintenance Manual.

Result: Battery is working properly. Proceed to test step 3.

3. Auxiliary Devices

A. Check if the battery is being drained because auxiliary devices are constantly in the ON position.

Result: The battery was depleted because the auxiliary device remained in the ON position.

Repair: Charge the battery. Verify that the battery can maintain its charge. Refer to system operation/testing and adjustment for the correct procedures.

Result: The auxiliary device remained in the ON position, but the battery was not depleted.

Please contact the Dealer Solutions Network (DSN).